Before inspection, set the vehicle to the pre-inspection condition.
Turn the ignition switch to the "LOCK" (OFF) position and then connect the MUT-II/IIII
to the diagnosis connector or connect a tachometer to the engine speed detection connector.
Disconnect the ventilation hose from the PCV valve, and connect a vacuum gauge to the
ventilation hose.
Plug the PCV valve.
Start the engine and check that idle speed is within the standard valve.
Standard value
: 680 ±
100 r/min
Check the intake manifold vacuum.
Limit: Minimum 60 kPa
Turn the ignition switch to the "LOCK" (OFF) position.
Remove the vacuum gauge and then connect the ventilation hose.