Terminal No.
|
Check item
|
Check conditions
|
Normal condition
|
1
|
Throttle position sensor input
|
Accelerator pedal: Depressed
|
4.4 -
5.3V
|
Accelerator pedal: Released
|
0.535 -
0.735 V
|
2
|
Engine-A/T-ECU output (Idle switch)
|
Accelerator pedal: Depressed
|
4.0 -
5.5 V
|
Accelerator pedal: Released
|
2.5 V or less
|
3
|
A/T control output
|
Driving on level road (No OD-OFF request)
|
System voltage
|
Driving on uphill road (OD-OFF request)
|
0 V
|
4
|
Stop lamp switch input
|
Brake pedal: Depressed
|
When stop lamp switch is ON
|
System voltage
|
Brake pedal: Released
|
When stop lamp switch is OFF
|
0 V
|
5
|
Auto-cruise vacuum pump power supply
|
Ignition switch: ON
Stop lamp switch: OFF
|
10 V or more
|
6
|
Auto-cruise control-ECU power supply
|
Ignition switch: ON
|
System voltage
|
7
|
Auto-cruise vacuum pump release valve
|
When decelerating with the auto-cruise control SET switch while driving at constant speed
|
1 V or less
|
8
|
Auto-cruise vacuum pump control valve
|
10 V or more
|
7
|
Auto-cruise vacuum pump release valve
|
When cancelling constant speed driving with the auto-cruise control CANCEL switch
|
10 V or more
|
8
|
Auto-cruise vacuum pump control valve
|
System voltage
|
9
|
Auto-cruise control switch input
|
MAIN switch: ON
|
Approximately 7.0 V
|
When input switch has not been operated
|
All switches: OFF
|
3.5 -
5.0 V
|
When input switch is pushed down
|
SET switch: ON
|
0.4 -
2.3 V
|
When input switch is pushed up
|
RESUME switch: ON
|
2.3 -
3.5 V
|
When input switch is pulled forward
|
CANCEL switch: ON
|
0.4 V or less
|
10
|
Vehicle speed signal input
|
When vehicle is moved forwards and backwards, signal turns ON and OFF repeatedly
|
When signal is ON
|
0 V
|
When signal is OFF
|
8 -
12 V*
|
12
|
Auto-cruise control-ECU power supply
|
Ignition switch: ON
MAIN switch: ON
|
System voltage
|
13
|
Inhibitor switch input
|
Select lever: Other than N or P range
|
System voltage
|
Select lever: N or P range
|
0 V
|
14
|
Earth
|
At any time
|
0 V
|
15
|
Auto-cruise control indicator lamp input
|
MAIN switch: ON (When indicator lamp is illuminated)
|
0 V
|
MAIN switch: OFF (When indicator lamp is switch off)
|
System voltage
|
16
|
Auto-cruise vacuum pump motor input
|
When driving at constant speed using the SET switch
|
Motor stopped/running
|
System voltage/0 V
|
When accelerating with the RESUME switch while driving at constant speed
|
Motor stopped/running
|
System voltage/0 V
|
When decelerating with the SET switch while driving at constant speed
|
Motor stopped
|
System voltage
|
When cancelling constant speed driving with the CANCEL switch
|
Motor stopped
|
System voltage
|
NOTE: *: Auto-cruise control-ECU terminal No.10 is sending a voltage of 5 volts to the vehicle speed signal system circuit. However, as higher voltage is mixed through the circuit a voltmeter will show 8 -
12 V.