Code No. P0403:
Exhaust Gas Recirculation (EGR) Control Solenoid Valve
|
|
OPERATION
- Power is supplied to the exhaust gas recirculation control
solenoid valve (terminal No. 1) from the engine control relay (terminal No. 1).
- The engine-A/T-ECU (terminal No. 6) makes the power transistor in the unit be in
"ON", and that makes currents go on the exhaust gas recirculation control solenoid valve (terminal
No. 2).
|
FUNCTION
- In response to the signal from the engine-A/T-ECU, the
exhaust gas recirculation control solenoid valve controls the operation of the exhaust gas recirculation
valve.
|
TROUBLE JUDGMENT
Check Condition
- Battery voltage 10 V or more.
Judgment Criterion
- When the EGR control solenoid valve is turned to "OFF" position from "ON" position,
none of solenoid coil surge voltage (battery voltage of +2 V) is detected.
|
PROBABLE CAUSE
- Failed EGR control solenoid valve
- Open/short circuit in EGR control solenoid valve circuit or loose connector contact
|
| |
| |
| STEP 1. MUT-II/III actuator test
- Refer to Actuator test reference table list
.
- Item 10: Exhaust gas recirculation control solenoid valve
OK: Operating sound can be heard and the valve vibrates.
Q: Is the check result normal?
YES:
Intermittent malfunction (Refer to GROUP 00 -
How to Use Troubleshooting/Inspection
Service Points  ).
NO:
Go to Step 2  .
|
| STEP 2. Connector check: B-102 EGR control solenoid valve connector
|
|
Q: Is the check result normal?
YES:
Go to Step 3  .
NO:
Repair.
|
| STEP 3. Perform resistance measurement at B-102 EGR control solenoid
valve connector.
|
|
- Disconnect connector, and measure at solenoid valve side.
- Resistance between terminal No. 1 and No. 2.
OK: 29 -
35 Ω
(at 20°C)
Q: Is the check result normal?
YES:
Go to Step 4  .
NO:
Replace EGR control solenoid valve.
|
| STEP 4. Perform voltage measurement at B-102 EGR control solenoid
valve connector.
|
|
- Disconnect connector, and measure at harness side.
- Voltage between terminal No. 1 and earth.
OK: System voltage
Q: Is the check result normal?
YES:
Go to Step 6  .
NO:
Go to Step 5  .
|
| STEP 5. Connector check: B-17X engine control relay connector
|
|
Q: Is the check result normal?
YES:
- Check and repair harness between B-102 (terminal No.
1) EGR control solenoid valve connector and B-17X (terminal No. 1) engine control relay connector.
- Check power supply line for open/short circuit.
NO:
Repair.
|
| STEP 6. Perform resistance measurement at C-112 engine-A/T-ECU connector.
|
|
- Disconnect connector, and measure at harness side.
- Voltage between terminal No. 6 and earth.
OK: System voltage
Q: Is the check result normal?
YES:
Go to Step 8  .
NO:
Go to Step 7  .
|
| STEP 7. Connector check: C-112 engine-A/T-ECU connector
|
|
Q: Is the check result normal?
YES:
- Check and repair harness between B-102 (terminal No.
2) EGR control solenoid valve connector and C-112 (terminal No. 6) engine-A/T-ECU connector.
- Check output line for open/short circuit.
NO:
Repair.
|
| STEP 8. Connector check: C-112 engine-A/T-ECU connector
|
|
Q: Is the check result normal?
YES:
Go to Step 9  .
NO:
Repair.
|
| STEP 9. Check harness between B-102 (terminal No. 2) exhaust gas recirculation
control solenoid valve connector and C-112 (terminal No. 6) engine-A/T-ECU connector.
|
|
- Check output line for damage.
Q: Is the check result normal?
YES:
Go to Step 10  .
NO:
Repair.
|
| STEP 10. Check harness between B-102 (terminal No. 1) exhaust gas
recirculation control solenoid valve connector and B-17X (terminal No. 1) engine control relay
connector.
|
|
- Check power supply line for damage.
Q: Is the check result normal?
YES:
Go to Step 11  .
NO:
Repair.
|
| STEP 11. MUT-II/III actuator test
- Refer to actuator test reference table list
.
- Item 10: Exhaust gas recirculation control solenoid valve
OK: Operating sound can be heard and the valve vibrates.
Q: Is the check result normal?
YES:
Intermittent malfunction (Refer to GROUP 00 -
How to Use Troubleshooting/Inspection
Service Points  ).
NO:
Replace engine-A/T-ECU.
|