Connect a manual pump (pressure-application type) to nipple.
CAUTION
In order to avoid damage to the diaphragm, do not apply a pressure
of 60 kPa or higher.
While gradually applying pressure, check the pressure that begins to activate (approximately
1 mm stroke) the waste gate actuator rod.
Standard value: Approximately 80 kPa
If there is a significant deviation from the standard value, check the actuator or
the waste gate valve: replace actuator or turbocharger assembly if necessary.
[15] INTAKE AND EXHAUST - - ON-VEHICLE SERVICE - WASTE