| INSTALLATION SERVICE POINTS
|
| >>A<<
O-RING /WATER INLET PIPE INSTALLATION
Replace the O-rings of the water inlet pipe with new ones and wet the peripheries with
water for easy insertion into the water pump and thermostat case.
 CAUTION
- Never allow any oil or
grease to touch the O-rings.
- Clamp the water inlet pipe only after installation of the thermostat case.
|
| |
| >>B<<
THERMOSTAT HOUSING INSTALLATION
|
|
Apply a 3 mm diameter bead of FIPG to the surface indicated in the drawing.
Specified sealant:
- Mitsubishi Genuine Part No.MD970389 or equivalent
|
| |
| >>C<<
ENGINE COOLANT TEMPERATURE GAUGE UNIT INSTALLATION
|
|
If the engine coolant temperature gauge unit is to be reused, apply the specified sealant
to its threads.
Specified sealant:
- 3M Nut Locking Part No.4171 or equivalent
|
| |
| >>D<<
ENGINE COOLANT TEMPERATURE SENSOR INSTALLATION
|
|
 CAUTION
When using a tool, avoid letting it touch the connector which
is made of plastic.
Apply the specified sealant to the threads of the sensor.
Specified sealant:
- 3M ATD Part No.8660 or equivalent
|