DOOR MIRROR ASSEMBLY OPERATION CHECK
Remove the door trim, and then connect the battery to the door mirror assembly connector to check that the door mirror operates.
   
Battery connection
Direction operation
  • Connect terminal 3 to the negative battery terminal.
  • Connect terminal 5 to the positive battery terminal.
Up
  • Connect terminal 3 to the positive battery terminal.
  • Connect terminal 5 to the negative battery terminal.
Down
  • Connect terminal 3 to the negative battery terminal.
  • Connect terminal 4 to the positive battery terminal.
Right
  • Connect terminal 3 to the positive battery terminal.
  • Connect terminal 4 to the negative battery terminal.
Left
  • Connect terminal 6 to the positive battery terminal.
  • Connect terminal 7 to the negative battery terminal.
Retract
  • Connect terminal 6 to the negative battery terminal.
  • Connect terminal 7 to the positive battery terminal.
Return

DOOR MIRROR CONTROL SWITCH CONTINUITY CHECK
   
Switch position
Tester connection
Specified condition
OFF
1 - 2, 1 - 3, 1 - 4, 1 - 6, 1 - 10, 1 - 11, 2 - 9, 3 - 9, 6 - 9, 9 - 10, 9 - 11
Open circuit
Left side
OFF
1 - 6, 1 - 10, 1 - 11, 6 - 9, 9 - 10, 9 - 11
Open circuit
Up
1 - 6, 9 - 11
Less than 2 ohms
Down
1 - 11, 6 - 9
Right
1 - 6, 9 - 10
Left
1 - 10, 6 - 9
Right side
OFF
1 - 2, 1 - 3, 1 - 6, 2 - 9, 3 - 9, 6 - 9
Open circuit
Up
1 - 6, 3 - 9
Less than 2 ohms
Down
1 - 3, 6 - 9
Right
1 - 6, 2 - 9
Left
1 - 2, 6 - 9
Retract and return
1 - 4
Less than 2 ohms