INSPECTION PROCEDURE E-2: Keyless entry hazard warning lamp answerback function or the room lamp answerback function does not work normally.
 CAUTION
Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.
COMMENTS ON TROUBLE SYMPTOM
If the hazard warning lamp and the room lamp work normally, the ETACS-ECU may be defective.
Alternatively, it is possible that the keyless entry hazard warning lamp answerback function was disabled by the adjustment function.
POSSIBLE CAUSES
  • Defective turn-signal lamp
  • Malfunction of the room lamp
  • Malfunction of the ETACS-ECU
  • Damaged harness wires and connectors
DIAGNOSIS PROCEDURE
Step 3. Check the operation of the room lamps.
Check that the room lamps illuminate normally.
Q: Is the check result normal?
YES:  Go to Step 4
.
NO:  Refer to Inspection Procedure O-2 "The front or rear room lamp does not illuminate/extinguish ."
©2004 Mitsubishi Motors Corporation