INSPECTION PROCEDURE M-1: The turn-signal lamps do not illuminate.
|
|  CAUTION
Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.
|
| |
| COMMENTS ON TROUBLE SYMPTOM
If all the turn-signal lamps do not illuminate, the ignition switch (IG1), the turn-signal lamp switch input circuit or the ETACS-ECU may be defective.
|
| POSSIBLE CAUSES
- Malfunction of the column switch
- Malfunction of the ETACS-ECU
- Damaged harness wires and connectors
|
| |
| |
| Step 1. Check that the hazard warning lamps operate.
Check that the hazard warning lamps illuminate normally.
Q: Is the check result normal?
YES:
Go to Step 6  .
NO:
Go to Step 2  .
|
| Step 2. Connector check: C-217 ETACS-ECU connector
Q: Is the check result normal?
YES:
Go to Step 3  .
NO:
Repair the defective connector.
|
| Step 3. Measure the voltage at the C-217 ETACS-ECU connector.
- Remove the ETACS-ECU, and measure at the junction block side.
- Voltage between C-217 ETACS-ECU connector terminal No.11 and body earth
OK: Battery positive voltage
Q: Is the check result normal?
YES:
Go to Step 5  .
NO:
Go to Step 4  .
|
| Step 4. Check the wiring harness between C-217 ETACS-ECU connector terminal No.11 and the battery.
NOTE: Prior to the wiring harness inspection, check intermediate connector C-116 and junction block connector C-202, and repair if necessary.
- Check the power supply line for open circuit.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How to Cope with Intermittent Malfunction  ).
NO:
Repair the wiring harness.
|
| Step 5. Retest the system.
Check that the turn-signal lamps illuminate normally.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How to Cope with Intermittent Malfunction  ).
NO:
Replace the ETACS-ECU.
|
|
Check the input signals below, which are related to the turn-signal lamp illumination.
System switch
|
Check condition
|
Turn-signal lamp switch (RH)
|
When the turn-signal lamp switch (RH) is turned from off to on
|
Turn-signal lamp switch (LH)
|
When the turn-signal lamp switch (LH) is turned from off to on
|
OK: The MUT-II/III sounds or the voltmeter needle fluctuates.
Q: Is the check result normal?
All the signals are received normally.:
Go to Step 7  .
The turn-signal lamp switch (RH) signal is not received.:
Refer to Inspection Procedure P-5 "The column switch (lighting and turn-signal lamp switch) signal is not received  ."
The turn-signal lamp switch (LH) signal is not received.:
Refer to Inspection Procedure P-5 "The column switch (lighting and turn-signal lamp switch) signal is not received  ."
|
| Step 7. Retest the system.
Check that the turn-signal lamps illuminate.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How to Cope with Intermittent Malfunction  ).
NO:
Replace the ETACS-ECU.
|