INSPECTION PROCEDURE O-1: The front or rear room lamp does not illuminate or extinguish normally. <Vehicles without keyless entry system>
|
|  CAUTION
Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.
|
| |
| COMMENTS ON TROUBLE SYMPTOM
The ETACS-ECU operates this function in accordance with the input signals below.
- Driver's door lock actuator
If this function does not work normally, these input signal circuit(s) or the ETACS-ECU may be defective.
|
| POSSIBLE CAUSES
- Malfunction of the door switches
- Malfunction of the driver's door lock actuator
- Malfunction of the ETACS-ECU
- Damaged harness wires and connectors
|
| |
| |
| Step 1. Check the power supply circuit.
When the ignition switch is turned to the LOCK (OFF) position, check if the hazard warning lamps illuminate.
Q: Is the check result normal?
YES:
Go to Step 2  .
NO:
Refer to Inspection Procedure A-2 "Check the ETACS-ECU battery power supply circuit  ."
|
|
Check the input signals below, which are related to the front and rear room lamps.
System switch
|
Check condition
|
Ignition switch (IG1)
|
When turned from ACC to ON
|
All of the door switches
|
A door is opened when all the doors are closed
|
Driver's door lock actuator switch
|
When the driver's door is unlocked or locked
|
OK: The MUT-II/III sounds or the voltmeter needle fluctuates.
Q: Is the check result normal?
All the signals are received normally.:
Go to Step 3  .
The ignition switch (IG1) signal is not received.:
Refer to Inspection Procedure P-2 "The ignition switch (IG1) signal is not received  ."
All the door switch signals are not received.:
Refer to Inspection Procedure P-12 "All the door switch signals are not received <LH drive vehicles>  ." Refer to Inspection Procedure P-12 "All the door switch signals are not received <RH drive vehicles>  ."
The driver's door lock actuator switch signal is not received.:
Refer to Inspection Procedure P-13 "The driver's door lock actuator switch signal is not received <LH drive vehicles>  ." Refer to Inspection Procedure P-13 "The driver's door lock actuator switch signal is not received <RH drive vehicles>  ."
|
| Step 3. Connector check: D-05 front room lamp connector, D-11 rear room lamp connector
Q: Is the check result normal?
YES:
Go to Step 4  .
NO:
Repair the defective connector.
|
| Step 4. Check the bulbs of the front or rear room lamps.
Check that the front or rear room lamp bulbs are not burned out.
Q: Is the check result normal?
YES:
Go to Step 5  .
NO:
Replace the front or rear room lamp bulb.
|
| Step 5. Connector check: C-217 ETACS-ECU connector
Q: Is the check result normal?
YES:
Go to Step 6  .
NO:
Repair the defective connector.
|
| Step 6. Check the wiring harness from C-217 ETACS-ECU connector terminal Nos.5 and 6 to D-05 front room lamp connector terminal Nos.2 and 1.
NOTE: Prior to the wiring harness inspection, check junction block connector C-210, and repair if necessary.
Q: Is the check result normal?
YES:
Go to Step 7  .
NO:
Repair the wiring harness.
|
| Step 7. Check the wiring harness from C-217 ETACS-ECU connector terminal Nos.5 and 6 to D-11 rear room lamp connector terminal Nos.2 and 1.
NOTE: Prior to the wiring harness inspection, check junction block connector C-210, and repair if necessary.
Q: Is the check result normal?
YES:
Go to Step 8  .
NO:
Repair the wiring harness.
|
| Step 8. Retest the system.
Check that the front or rear room lamp illuminates and extinguishes normally.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How to Cope with Intermittent Malfunction  ).
NO:
Replace the ETACS-ECU.
|