Step 3. Function diagnosis by using the SWS monitor
Check the SWS communication signal, which are related to the power window timer function.
<Selected item>
POWER WINDOW
- Turn the ignition switch from the ON to the OFF position.
Item No.
|
Item name
|
Normal condition
|
30
|
IG SW IG1
|
OFF
|
33
|
P/W SW ACCEPT
|
PERMIT
|
71
|
P/W ECU ACK
|
NORMAL ACK
|
NOTE: For item No.33 "P/W SW ACCEPT", "PERMIT" is displayed for approximately 30 seconds after the ignition switch is turned off, and then change to "PROHIBIT". In addition, on item No.71 "P/W MODULE", "NORMAL ACK" is changed to "INPUT CHECK" momentarily, when the power window main switch is operated for approximately 30 seconds after the ignition switch is turned off.
OK: Normal conditions are displayed for all the items.
Q: Is the check result normal?
Normal conditions are displayed for all the items.:
Go to Step 4

.
Normal condition is not displayed for item No.30:
Refer to Inspection Procedure P-2 "The ignition switch (IG1) signal is not received

."
Normal condition is not displayed for item No.33:
Replace the ETACS-ECU.
Normal condition is not displayed for item No.71:
Replace the power window main switch.