INSPECTION PROCEDURE M-1: The turn-signal lamps do not illuminate.
|
|  CAUTION
Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.
|
| |
| COMMENTS ON TROUBLE SYMPTOM
If all the turn-signal lamps do not illuminate, the ignition switch (IG1), the turn-signal lamp switch input circuit or the ETACS-ECU may be defective.
|
| POSSIBLE CAUSES
- Malfunction of the column switch
- Malfunction of the ETACS-ECU
- Damaged harness wires and connectors
|
| |
| |
| Step 1. Check that the hazard warning lamps operate.
Check that the hazard warning lamps illuminate normally.
Q: Is the check result normal?
YES:
Go to Step 6  .
NO:
Go to Step 2  .
|
| Step 2. Connector check: C-217 ETACS-ECU connector
Q: Is the check result normal?
YES:
Go to Step 3  .
NO:
Repair the defective connector.
|
| Step 3. Measure the voltage at the C-217 ETACS-ECU connector.
- Remove the ETACS-ECU, and measure at the junction block side.
- Voltage between C-217 ETACS-ECU connector terminal No.11 and body earth
OK: Battery positive voltage
Q: Is the check result normal?
YES:
Go to Step 5  .
NO:
Go to Step 4  .
|
| Step 4. Check the wiring harness between C-217 ETACS-ECU connector terminal No.11 and the battery.
NOTE: Prior to the wiring harness inspection, check intermediate connector C-116 and junction block connector C-202, and repair if necessary.
- Check the power supply line for open circuit.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How to Cope with Intermittent Malfunction  ).
NO:
Repair the wiring harness.
|
| Step 5. Retest the system.
Check that the turn-signal lamps illuminate normally.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How to Cope with Intermittent Malfunction  ).
NO:
Replace the ETACS-ECU.
|
| Step 6. Function diagnosis by using the SWS monitor
Check the SWS communication signal, which are related to the right turn-signal lamps.
<Selected item>
TURN SIGNAL - TURN-SIG. RH
- Turn-signal lamp switch: RH
Item No.
|
Item name
|
Normal condition
|
Item 10
|
TURN SIG.RH
|
ON
|
Item 11
|
TURN SIG.LH
|
OFF
|
Item 30
|
IG SW(IG1)
|
ON
|
OK: Normal conditions displayed for all the items
Q: Is the check result normal?
Normal conditions are displayed for all the items.:
Go to Step 7  .
Normal condition is not displayed for item 10 or 11.:
Refer to Inspection Procedure P-5 "The column switch (lighting and turn-signal lamp switch) signal is not received  ."
Normal condition is not displayed for item No.30.:
Refer to Inspection Procedure P-2 "The ignition switch (IG1) signal is not received  ."
|
| Step 7. Function diagnosis by using the SWS monitor
Check the SWS communication signal, which are related to the left turn-signal lamps.
<Selected item>
TURN SIGNAL - TURN-SIG. LH
- Turn-signal lamp switch: LH
Item No.
|
Item name
|
Normal condition
|
Item 10
|
TURN SIG.RH
|
OFF
|
Item 11
|
TURN SIG.LH
|
ON
|
OK: Normal condition is displayed.
Q: Is the check result normal?
Normal conditions are displayed for all the items.:
Go to Step 8  .
Normal condition is not displayed for item 10 or 11.:
Refer to Inspection Procedure P-5 "The column switch (lighting and turn-signal lamp switch) signal is not received  ."
|
| Step 8. Retest the system.
Check that the turn-signal lamps illuminate.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How to Cope with Intermittent Malfunction  ).
NO:
Replace the ETACS-ECU.
|