INSPECTION PROCEDURE O-4: The door-ajar warning lamp does not illuminate/extinguish normally.
|
|  CAUTION
Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.
|
| |
| OPERATION
The ETACS-ECU operates this function in accordance with all the door switch signals. If the door-ajar warning lamp does not work normally, the input signal circuits from all the door switches or the ETACS-ECU may be defective.
|
| POSSIBLE CAUSES
- All the door switches are defective.
- Malfunction of the ETACS-ECU
- Damaged harness wires and connectors
|
| |
| |
| Step 1. Check the operation of the room lamp.
Check that the room lamps illuminate and extinguish normally.
Q: Is the check result normal?
YES:
Go to Step 2  .
NO:
Refer to Inspection Procedure O-1 "The front or rear room lamp does not illuminate or extinguish <vehicles without keyless entry system>
 ." Or refer to inspection procedure O-2 "The front or rear room lamp does not illuminate or extinguish <vehicles with keyless entry system>
 ."
|
| Step 2. SWS monitor data list
Check the input signals below, which are related to the door-ajar warning lamp.
<Selected item>
ETACS ECU
Item No.
|
Item name
|
Normal condition
|
Item 32
|
DR DOOR SW*1
|
ON
|
FRONT DOOR SW*2
|
NOTE: - *1
: Except for Australia
- *2
: Vehicles for Australia
OK: Normal condition is displayed.
Q: Is the check result normal?
YES:
Go to Step 3  .
NO:
Refer to Inspection Procedure P-4 "The driver's door switch signal is not received <LH drive vehicles>  ." Refer to Inspection Procedure P-4 "The driver's door switch signal is not received <RH drive vehicles>  ."
|
|
Check the input signals below, which are related to the door-ajar warning lamp.
System switch
|
Check condition
|
All of the door switches
|
A door is opened when all the doors are closed
|
OK: The MUT-II/III sounds or the voltmeter needle fluctuates.
Q: Is the check result normal?
YES:
Go to Step 4  .
NO:
Refer to Inspection Procedure P-14 "All the door switch signals are not received <LH drive vehicles>  ." Refer to Inspection Procedure P-14 "All the door switch signals are not received <RH drive vehicles>  ."
|
| Step 4. Connector check: C-05 combination meter connector
Q: Is the check result normal?
YES:
Go to Step 5  .
NO:
Repair the defective connector.
|
| Step 5. Check the door-ajar warning lamp bulb.
Check the door-ajar warning lamp bulb.
Q: Is the check result normal?
YES:
Go to Step 6  .
NO:
Replace the door-ajar warning lamp bulb.
|
| Step 6. Connector check: C-217 ETACS-ECU connector
Q: Is the check result normal?
YES:
Go to Step 7  .
NO:
Repair the defective connector.
|
| Step 7. Check the wiring harness from C-217 ETACS-ECU connector (terminal Nos.53 and 71) to C-05 combination meter connector (terminal Nos.20 and 21).
Q: Is the check result normal?
YES:
Go to Step 8  .
NO:
Repair the wiring harness.
|
| Step 8. Retest the system.
Replace the ETACS-ECU, and then check that the door-ajar warning lamp illuminates/extinguishes normally.
- Replace the ETACS-ECU.
- Check that the door-ajar warning lamp illuminates/extinguishes normally.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How to Cope with Intermittent Malfunction  ).
NO:
Replace the combination meter.
|