INSPECTION PROCEDURE
N-3: Either of the front fog lamp(s) does not illuminate normally.
|
|  CAUTION
Whenever the ECU is replaced,
ensure that the input and output signal circuits are normal.
|
| |
| COMMENTS ON TROUBLE SYMPTOM
If any of the front fog lamps do not illuminate, the wiring harness connector(s), the
bulb or the fuse may be defective or burned out.
|
| POSSIBLE CAUSES
- Burned-out front fog lamp bulb
- Damaged harness wires and connectors
|
| |
| |
| Step 1. Connector check: A-24 <RH>
or
A-19 <LH>
front fog lamp connector, or C-05 <front fog lamp indicator lamp>
combination
meter connector
Q: Is the check result normal?
YES:
Go to Step 2  .
NO:
Repair the defective connector.
|
| Step 2. Check the bulbs of the front fog lamps or the front fog lamp
indicator lamp.
Check the bulb(s) of the defective lamp.
Q: Is the check result normal?
YES:
Go to Step 3  .
NO:
Replace the bulb(s) of the defective lamp.
|
| Step 3. Measure the resistance at A-24 <RH>
or A-19 <LH>
front
fog lamp connector, or C-05 <front fog lamp indicator lamp>
combination meter
connector.
- Disconnect the connector, and measure at the wiring harness side.
- Check the resistance between the lamp connector and body earth.
- Resistance between A-24 <RH>
front
fog lamp connector terminal No.2 and body earth
- Resistance between A-19 <LH>
front fog lamp connector terminal
No.2 and body earth
- Resistance between C-05 <front fog lamp indicator lamp>
combination
meter connector terminal No.12 and body earth
OK: 2 Ω
or less
Q: Is the check result normal?
YES:
Go to Step 5  .
NO:
Go to Step 4  .
|
| Step 4. Check the wiring harness from A-24 <RH>
or
A-19 <LH>
front fog lamp connector terminal No.2 or C-05 <front fog
lamp indicator lamp>
combination meter connector terminal No.12 to body earth.
- Check the earth wires for open circuit.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How
to Cope with Intermittent Malfunction  ).
NO:
Repair the wiring harness.
|
| Step 5. Connector check: A-05X fog lamp relay connector
Q: Is the check result normal?
YES:
Go to Step 6  .
NO:
Repair the defective connector.
|
| Step 6. Check the wiring harness from A-24 <RH>
or
A-19 <LH>
front fog lamp connector terminal No.1 or C-05 <front fog
lamp indicator lamp>
combination meter connector terminal No.7 to A-05X fog lamp relay
connector terminal No.4.
NOTE: Prior to the wiring harness inspection, check intermediate connector C-116 <front
fog lamp indicator lamp>, and repair if necessary.
- Check the output lines for open circuit.
Q: Is the check result normal?
YES:
Go to Step 7  .
NO:
Repair the wiring harness.
|
| Step 7. Retest the system.
Check that the fog lamp and the front fog lamp indicator lamp illuminate normally.
Q: Is the check result normal?
The lamps illuminate normally at both high and low beams.:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How
to Cope with Intermittent Malfunction  ).
The fog lamps do not illuminate.:
Replace the fog lamp(s).
The front fog lamp indicator lamp does not illuminate.:
Replace the combination meter.
|