INSPECTION PROCEDURE
L-2: The hazard warning lamps do not illuminate.
|
|  CAUTION
Whenever the ECU is replaced,
ensure that the input and output signal circuits are normal.
|
| |
| COMMENTS ON TROUBLE SYMPTOM
If the hazard warning lamps do not illuminate, the hazard warning lamp input signal circuit
or the ETACS-ECU may be defective.
|
| POSSIBLE CAUSES
- Malfunction of the hazard warning lamp switch
- Malfunction of the ETACS-ECU
- Damaged harness wires and connectors
|
| |
| |
| Step 1. Check that the turn-signal lamps operate.
Check that the turn-signal lamps illuminate normally.
Q: Is the check result normal?
YES:
Go to Step 2  .
NO:
Refer to inspection procedure L-1 "The turn-signal lamps do not illuminate"  .
|
| Step 2. Check the power supply circuit.
When the ignition switch is at the LOCK (OFF) position, check that the functions below
work normally.
- Ignition key reminder function
- Central door locking system
- Dome lamp (excluding interior lamp automatic shutdown function)
Q: Is the check result normal?
YES:
Go to Step 3  .
NO:
Refer to inspection procedure A-2 "Check the battery power supply circuit to the
ETACS-ECU  ."
|
|
Check the input signal from the hazard warning lamp switch.
System switch
|
Check conditions
|
Hazard warning lamp switch
|
When the hazard warning lamp switch is turned from off to on
|
OK: The MUT-II/III sounds or the voltmeter needle fluctuates.
Q: Is the check result normal?
YES:
Go to Step 4  .
NO:
Refer to inspection procedure P-12 "The hazard warning lamp switch signal is not
received"  .
|
| Step 4. Retest the system.
Check that the hazard warning lamps illuminate.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How
to Cope with Intermittent Malfunction  ).
NO: