INSPECTION PROCEDURE
N-3: The door-ajar warning lamp does not illuminate/extinguish normally.
|
|  CAUTION
Whenever the ECU is replaced,
ensure that the input and output signal circuits are normal.
|
| |
| OPERATION
The ETACS-ECU operates this function in accordance with all the door switch signals. If
the door-ajar warning lamp does not work normally, the input signal circuits from all the door switches
or the ETACS-ECU may be defective.
|
| POSSIBLE CAUSES
- All the door switches are defective.
- Malfunction of the ETACS-ECU
- Damaged harness wires and connectors
|
| |
| |
| Step 1. Check the operation of the room lamp.
Check that the dome lamps illuminate and extinguish normally.
Q: Is the check result normal?
YES:
Go to Step 2  .
NO:
Refer to inspection procedure N-1 "The front and rear room lamp does not illuminate/extinguish  ."
|
|
Check the input signals below, which are related to the door-ajar warning lamp.
System switch
|
Check conditions
|
Driver's door switch
|
Driver's door is opened while all the other doors are closed.
|
All of the door switches
|
A door is opened when all the doors are closed
|
OK: The MUT-II/III sounds or the voltmeter needle fluctuates.
Q: Are the check result normal?
All the signals are received normally.:
Go to Step 3  .
The driver's door switch signal is not received.:
Refer to inspection procedure P-4 "The driver's door switch signal is
not received"  .
All the door switch signals are not received.:
Refer to inspection procedure P-13 "All the door switch signals are not received"  .
|
| Step 3. Connector check: C-05 combination meter connector
Q: Is the check result normal?
YES:
Go to Step 4  .
NO:
Repair the connector.
|
| Step 4. Check the door-ajar warning lamp bulb.
Check the door-ajar warning lamp bulb.
Q: Is the check result normal?
YES:
Go to Step 5  .
NO:
Replace the door-ajar warning lamp bulb.
|
| Step 5. Connector check: C-219 ETACS-ECU connector
Q: Is the check result normal?
YES:
Go to Step 6  .
NO:
Repair the connector.
|
| Step 6. Check the wiring harness from C-219 ETACS-ECU connector (terminal
Nos. 53 and 71) to C-05 combination meter connector (terminal Nos. 20 and 21).
Q: Is the check result normal?
YES:
Go to Step 7  .
NO:
Repair the wiring harness.
|
| Step 7. Retest the system.
Replace the ETACS-ECU, and then check that the door-ajar warning lamp illuminates/extinguishes
normally.
- Replace the ETACS-ECU.
- Check that the door-ajar warning lamp illuminates/extinguishes normally.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How
to Cope with Intermittent Malfunction  ).
NO:
Replace the combination meter.
|