|
| |
INSPECTION
PROCEDURE O-1: The security alarm is not armed. |
|
|
|  CAUTION
Whenever the ECU is replaced,
ensure that the input and output signal circuits are normal.
|
| |
| COMMENTS ON TROUBLE SYMPTOM
If the security alarm does not work normally, the input signal circuits to the components
below and security alarm indicator lamp or the ETACS-ECU may be defective.
- Keyless entry transmitter
Alternatively, it is possible that "SECURITY ALM" was set to "W/O FUNCTION" by
using the adjustment function.
|
| POSSIBLE CAUSES
- Malfunction of the security alarm indicator lamp
- Malfunction of the keyless entry transmitter
- Malfunction of the key reminder switch
- Malfunction of the ETACS-ECU
- Damaged harness wires and connectors
|
| |
| |
| Step 1. Check the adjustment function.
Check that "SECURITY ALM" is set to "HORN/HAZARD" or "HAZARD" by using the adjustment
function.
Q: Is the check result normal?
YES:
Go to Step 2  .
NO:
Set "SECURITY ALM" to "HORN/HAZARD" or "HAZARD" by using the adjustment
function.(Refer to  .)
|
| Step 2. Check the keyless entry system.
Check that the keyless entry system works normally.
Q: Is the check result normal?
YES:
Go to Step 3  .
NO:
Refer to inspection procedure E-1 "Keyless entry system does not work  ."
|
| Step 3. Confirm communication data by using the SWS monitor.
Check the SWS communication signal from the ignition switch (ACC) to the ETACS-ECU.
<Selected item>
ETACS ECU
Item No.
|
Item name
|
Normal conditions
|
Item 31
|
IG SW(ACC)
|
ON
|
OK: Normal condition is displayed.
Q: Is the check result normal?
YES:
Go to Step 4  .
NO:
Refer to inspection procedure P-1 "The ignition switch (ACC) signal is not received  ."
|
| Step 4. Check the ETACS SW data by using the SWS monitor.
Check the ETACS-ECU signal from the key reminder switch.
- Ignition switch: OFF (key inserted)
Item No.
|
Item name
|
Normal conditions
|
Item 03
|
KEY REMIN SW
|
OFF
|
OK: Normal condition is displayed.
Q: Is the check result normal?
YES:
Go to Step 5  .
NO:
Refer to inspection procedure P-10 "The key reminder switch signal is not received  ."
|
| Step 5. Connector check: C-122 security alarm indicator lamp connector
Q: Is the check result normal?
YES:
Go to Step 6  .
NO:
Repair the defective connector.
|
| Step 6. Check the security alarm indicator lamp.
Check that the security alarm indicator lamp illuminates.
Q: Is the check result normal?
YES:
Go to Step 7  .
NO:
Replace the security alarm indicator lamp.
|
| Step 7. Measure the voltage at C-122 security alarm indicator lamp
connector.
- Disconnect the connector, and measure at the wiring harness side.
- Voltage between C-122 security alarm indicator lamp connector terminal 1 and body
earth
OK: Battery positive voltage
Q: Is the check result normal?
YES:
Go to Step 9  .
NO:
Go to Step 8  .
|
| Step 8. Check the wiring harness between C-122 security alarm indicator
lamp connector terminal No.1 and fusible link (1).
NOTE: Prior to the wiring harness inspection, check intermediate connectors A-14, C-125, joint
connector C-02 and junction block connectors C-202, C-204 and repair if necessary.
- Check the power supply line for open or short circuit.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How
to Cope with Intermittent Malfunction  ).
NO:
Repair the wiring harness.
|
| Step 9. Connector check: C-219 ETACS-ECU connector
Q: Is the check result normal?
YES:
Go to Step 10  .
NO:
Repair the defective connector.
|
| Step 10. Check the wiring harness between C-219 ETACS-ECU connector
terminal No. 74 and C-122 security alarm indicator lamp connector terminal No.2.
- Check the power supply line for open or short circuit.
Q: Is the check result normal?
YES:
Go to Step 11  .
NO:
Repair the wiring harness.
|
| Step 11. Retest the system.
Check that the security alarm works normally.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How
to Cope with Intermittent Malfunction  ).
NO:
Replace the ETACS-ECU.
|