Step 3. Confirm communication data by using the SWS monitor.
Check the input signals below, which are related to the interior lamp automatic shutdown
function.
<Selected item>
ETACS
- Driver's door: Open (close only when item No.38 is to be checked)
- All the doors: Open any door when all the doors are closed (close only when item
No.32 is to be checked)
Item No.
|
Item name
|
Normal conditions
|
Item 30
|
IG SW(IG1)
|
OFF
|
Item 31
|
IG SW(ACC)
|
OFF
|
Item 32
|
DR DOOR SW
|
ON
|
Item 38
|
THEFT-ALARM
|
OFF→ON
|
OK: Normal condition is displayed.
Q: Are the check result normal?
Normal conditions are displayed for all the items.:
Go to Step 4

.
Normal condition is not displayed for item No.30.:
Refer to inspection procedure P-2 "The ignition switch (IG1) signal is not received"

.
Normal condition is not displayed for item No.31.:
Refer to inspection procedure P-1 "The ignition switch (ACC) signal is not received"

.
Normal condition is not displayed for item No.32.:
Refer to inspection procedure P-4 "The driver's door switch signal is
not received"

.
Normal condition is not displayed for item No.38.:
Refer to inspection procedure P-13 "All the door switch signals are not received"

.