INSPECTION PROCEDURE
I-1: Electric retractable remote controlled door mirror does not work at all.
|
|  CAUTION
Whenever the ECU is replaced,
ensure that the input and output signal circuits are normal.
|
| |
| COMMENTS ON TROUBLE SYMPTOM
If the electric retractable remote controlled door mirror does not work at all, these
power supply circuit(s), these earth circuit(s), remote controlled mirror switch or ETACS-ECU
may be defective.
|
| POSSIBLE CAUSES
- Malfunction of the remote controlled mirror switch
- Damaged harness wires and connectors
|
| |
| |
| Step 1. ECU check on the SWS monitor
Check that the power supply and earth lines to the ETACS-ECU and the SWS communication
lines are normal.
ECUS TO BE CHECKED
OK: "OK" is displayed on the "ETACS ECU" menu.
Q: Is the check result normal?
YES:
Go to Step 2  .
NO:
Refer to Inspection Procedure A-3 "Communication with the ETACS-ECU is not possible  ."
|
| Step 2. Confirm communication data by using the SWS monitor.
Check the SWS communication signal, which are related to the electric retractable remote
controlled mirror.
<Selected item>
ETACS ECU
Item No.
|
Item name
|
Normal conditions
|
Item 31
|
IG SW (ACC)
|
ON
|
OK: Normal condition is displayed.
Q: Is the check result normal?
YES:
Go to Step 3  .
NO:
Refer to inspection procedure P-1 "The ignition switch (ACC) signal is not received  ."
|
| Step 3. Check the ETACS SW data by using the SWS monitor.
Check the ETACS-ECU signal, which is related to the electric retractable remote controlled
mirror.
- Electric remote controlled mirror switch (folding/unfolding switch):
ON
Item No.
|
Item name
|
Normal conditions
|
Item 14
|
EL RET MIR SW
|
ON
|
OK: Normal condition is displayed
Q: Is the check result normal?
YES:
Go to Step 4  .
NO:
Refer to inspection procedure P-11 "Signal is not received from the electric remote
controlled mirror switch (folding/unfolding switch)  ."
|
| Step 4. Connector check: C-217 ETACS-ECU connector
Q: Is the check result normal?
YES:
Go to Step 5  .
NO:
Repair the connector.
|
| Step 5. Measure the voltage at the C-217 ETACS-ECU connector.
- Remove the ETACS-ECU, and measure at the junction block side.
- Check the voltage between the C-217 ETACS-ECU connector terminal No.2 and body
earth.
OK: Battery positive voltage
Q: Is the check result normal?
YES:
Go to Step 7  .
NO:
Go to Step 6  .
|
| Step 6. Check the wiring harness between C-217 ETACS-ECU connector
terminal No. 2 and the fusible link (1).
NOTE: Prior to the wiring harness inspection, check intermediate connectors A-14, C-125 and
junction block connector C-204, and repair if necessary.
- Check the power supply line to the battery for open circuit.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How
to Cope with Intermittent Malfunction  ).
NO:
Repair the wiring harness.
|
| Step 7. Retest the system.
Check that the electric retractable remote controlled mirror works normally.
Q: Is the check result normal?
YES:
The trouble can be an intermittent malfunction (Refer to GROUP 00 -
How
to Cope with Intermittent Malfunction  ).
NO:
Replace the ETACS-ECU.
|