- Turn the adjusting screw shown in the illustration to adjust the line pressure to the standard value. The pressure increases when the screw is turned anti-clockwise.
NOTE: When adjusting the line pressure, adjust to the middle of the standard value range.
Standard value: 1.01 -
1.05 MPa
(Change in pressure for a single full of the adjusting screw: 0.035 MPa)
- Install the valve body cover, and then pour in the specified amount of A/T fluid.
- Repeat the hydraulic pressure test. (Refer to
.) Readjust the line pressure if necessary.