- Measure the resistance between A/T control solenoid valve assembly connector terminals 1 and 2.
Standard value:
A/T fluid temperature (°C)
|
Resistance value (Ω)
|
0
|
16.7 -
20.5
|
20
|
7.3 -
8.9
|
40
|
3.4 -
4.2
|
60
|
1.9 -
2.2
|
80
|
1.0 -
1.2
|
100
|
0.57 -
0.69
|
NOTE: The N range indicator <Vehicles for Hong Kong spec.>
or A/T fluid temperature warning lamp <Except for Hong Kong spec.>
on the combination meter flashes when the temperature reaches approximately 125 °C or higher and then stops flashing when the temperature drops below approximately 115°C.
- If the A/T fluid temperature sensor resistance and the temperature when the N range indicator is flashing or switched off are outside the standard value ranges, replace the A/T fluid temperature sensor.