Item No.
|
Inspection item
|
Test description
|
Inspection condition
|
Normal status
|
01
|
LR solenoid valve
|
Actuate solenoid valve indicated by MUT-II/III for 5 seconds at duty ratio of 50%.
Other remaining solenoid valve are not ON.
|
- Selector lever position: P
- Accelerator pedal: Released
|
When solenoid valve is actuated, operating sound is audible.
|
02
|
UD solenoid valve
|
03
|
2ND solenoid valve
|
04
|
OD solenoid valve
|
05 <5A/T>
|
RED solenoid valve
|
06
|
DCC solenoid valve
|
07
|
1st indicator lamp
|
Illuminate shift indicator indicated by MUT-II/III for 3 seconds
|
Shift indicator is displayed.
|
08
|
2nd indicator lamp
|
09
|
3rd indicator lamp
|
10
|
4th indicator lamp
|
11 <5A/T>
|
5th indicator lamp
|
12
|
A/T control relay
|
A/T control relay is OFF for three seconds.
|
Data list No.54
- Normal: System voltage (V)
|
15 <5A/T>
|
Downshift forbidden buzzer
|
Let the ETACS-ECU to sound the downshift forbidden buzzer.
|
The buzzer sounds.
|