OPERATION CHECK
       
    1. Disconnect the oil control valve connector.
     CAUTION
    To prevent the coil from burning, keep the duration of the voltage application as short as possible.
    1. Apply battery voltage to the terminals of the connector at the oil control valve, and make sure the oil control valve makes a clicking sound.
    MEASUREMENT OF RESISTANCE BETWEEN TERMINALS
    1. Disconnect the oil control valve connector.
    1. Measure the resistance between the terminals of the connector at the oil control valve.
    Standard value: 6.9 - 7.9 Ω (at 20°C)
    1. If resistance is outside the standard value, replace the oil control valve.
    ©2004 Mitsubishi Motors Corporation