- Check the refrigerant level (bubble state) through the sight glass.
 CAUTION
Use the low-pressure service valve.
Items
|
State
|
Insufficient
|
Many bubbles are seen. If refrigerant is extremely low, it appears white.
|
Sufficient or excess refrigerant
|
No bubbles are seen.
|
NOTE:
- If insufficient, replenish the refrigerant as follows.
- Replenish until bubbles disappear from the sight glass.
- After the bubbles disappear from the sight glass, replenish 100 g of refrigerant.
- If excessive, replenish the refrigerant as follows.
- Drain the refrigerant until bubbles can be seen through the sight glass.
- Replenish until bubbles disappear from the sight glass.
- After the bubbles disappear from the sight glass, replenish 100 g of refrigerant.
|