| BLOWER RELAY CONTINUITY CHECK
|
|
Battery voltage
|
Tester connection
|
Specified condition
|
Not applied
|
4 -
5
|
Open circuit
|
- Connect terminal 1 to the positive battery terminal
- Connect terminal 3 to the negative battery terminal
|
4 -
5
|
Less than 2 ohms
|
|
| A/C COMPRESSOR RELAY CONTINUITY CHECK
|
|
Battery voltage
|
Tester connection
|
Specified condition
|
Not applied
|
1 -
4
|
Open circuit
|
- Connect terminal 3 to the positive battery terminal
- Connect terminal 2 to the negative battery terminal
|
1 -
4
|
Less than 2 ohms
|
|
| FAN CONTROL RELAY CONTINUITY CHECK
|
|
Battery voltage
|
Tester connection
|
Specified condition
|
Not applied
|
2 -
4
|
Open circuit
|
- Connect terminal 1 to the positive battery terminal
- Connect terminal 3 to the negative battery terminal
|
2 -
4
|
Less than 2 ohms
|
|