Terminal No.
|
Check item
|
Checking requirement
|
Normal condition
|
1
|
Rear window defogger switch
|
Rear window defogger switch: ON
|
0 V
|
Rear window defogger switch: OFF
|
System voltage
|
2
|
Inside/outside air changeover damper motor (outside air)
|
When the damper is moved to the inside air recirculation position
|
0 V
|
When the damper is moved to the outside air inside air intake position
|
System voltage
|
3
|
Inside/outside air changeover damper motor (inside air)
|
When the damper is moved to the inside air recirculation position
|
System voltage
|
When the damper is moved to the outside air inside air intake position
|
0 V
|
4
|
Output to the engine-A/T-ECU (A/C1)
|
A/C stopped
|
0 V
|
|
|
System voltage
|
5
|
Output to the engine-A/T-ECU (A/C2)
|
When the A/C is under low load
|
System voltage
|
When the A/C is under high load
|
0 V
|
6
|
Power supply to the A/C illumination
|
Lighting switch: ON
|
System voltage
|
7
|
-
|
-
|
-
|
8
|
Blower switch (lo)
|
blower switch: lo
|
System voltage
|
9
|
-
|
-
|
-
|
10
|
Power supply to the ignition switch (IG2)
|
Ignition switch: ON
|
System voltage
|
11
|
Earth to the A/C illumination
|
Always
|
0 V
|
12
|
Earth
|
Always
|
0 V
|
13
|
Air thermo sensor (outlet side)
|
Sensor probe temperature 25°C (1.5k ohm)
|
2.2 V
|
14
|
Air thermo sensor (inlet side)
|
Sensor probe temperature 25°C (1.5k ohm)
|
2.2 V
|
15
|
-
|
-
|
-
|
16
|
Earth to the air thermo sensor
|
Always
|
0 V
|