Item No.
|
Check items
|
Inspection conditions
|
Normal condition
|
11
|
Interior temperature sensor
|
Ignition switch: ON
|
Room temperature is the same as MUT-II displayed temperature.
|
13
|
Outside air temperature sensor
|
Ignition switch: ON
|
Outside temperature is the same as MUT-II displayed temperature.
|
15
|
Heater water temperature sensor
|
Ignition switch: ON
|
Heater core wall surface temperature is the same as MUT-II displayed temperature.
|
21
|
Air thermo sensor
|
Ignition switch: ON
|
Evaporator outlet temperate is the same as MUT-II displayed temperature
|
25
|
Photo sensor
|
- Change the volume of insolation.
|
The volume of insolation takes inverse proportion with the MUT-II displayed voltage.
|
31
|
Potentiometer for air mixing door
|
|
Opening angle: approximately 100%
|
|
|
Opening angle: approximately 0%
|
32
|
Potentiometer for mode selection damper
|
|
Opening angle: approximately 0%
|
|
|
Opening angle: approximately 60%
|
- Damper position: FOOT/DEF
|
Opening angle: approximately 80%
|
|
|
Opening angle: approximately 100%
|
42
|
A/C pressure sensor
|
|
Refrigerant pressure is the same as MUT-II displayed pressure.
|