CHECK AT A/C-ECU TERMINALS
   
Terminal No.
Check items
Check conditions
Normal conditions
1
Interior temperature sensor
Sensor temperature: 25°C (4kΩ)
2.1- 2.7V
2
Output to blower pulse controller
When the blower is operating.
0 - 2.5V (Effective alternating voltage)
3
Back-up power supply
Always
System voltage
4
Input from heater water temperature sensor
Sensor temperature: 25°C (4kΩ)
2.1 - 2.7V
5
Input from air mixing door control motor potentiometer
When the damper flaps is moving to the MAX HOT position.
4.1 - 4.6 V
6
Input from mode selection damper control motor potentiometer
When the damper is moved to the DEF position.
4.1 - 4.6 V
7
Input from the outside thermo sensor
Sensor temperature: 25°C (4kΩ)
2.1 - 2.7 V
8
Input from the air thermo sensor
Sensor temperature: 25°C (4kΩ)
2.1 - 2.7 V
9
Photo sensor (-)
Brightness is 0 lux
4.9 - 5.1 V
Brightness is 100000 lux or more
Approximately 0 V
10
Potentiometer power supply
Always
5 V
11
Input from the A/C pressure sensor
2.6 Mpa
3.9 V
12 - 15
-
-
-
16
Rear defogger
When the rear defogger is operating.
2.0 V or less
When the rear defogger is stopped
System voltage
17
Diagnosis set
Ignition switch: ON
A voltmeter needle fluctuates between 0 and 12 V.
18
Input from diagnosis
Ignition switch: ON
Approximately 5 V
19
Photo sensor (+)
Always
0 V
20
Sensors and potentiometers earth
Always
0 V
21
Air outlet changeover damper motor (FACE)
When the damper is moved to the FACE position.
10 V
When the damper is moved to the DEF position.
Faint voltage (0.5 V)
22
Air mix damper motor (MAX COOL)
When the damper flaps is moving to the MAX COOL position.
10 V
When the damper flaps is moving to the MAX HOT position.
Faint voltage (0.5 V)
23
outside/inside air selection damper control motor (outside)
When the damper is moved to the inside air recirculation position
10 V (When the motor is stopped)
When the damper is moved to the outside air inside air intake position
2.0 or less
24
Mode selection damper control motor and potentiometer (DEF)
When the damper is moved to the FACE position.
Faint voltage (0.5 V)
When the damper is moved to the DEF position.
10 V
25
Air mixing door control motor and potentiometer (MAX HOT)
When the damper flaps is moving to the MAX COOL position.
Faint voltage (0.5 V)
When the damper flaps is moving to the MAX HOT position.
10 V
26
outside/inside air selection damper control motor (inside)
When the damper is moved to the inside air recirculation position
2.0 V or less
When the damper is moved to the outside air inside air intake position
10 V (When the motor is stopped)
27
Earth
Always
Continuity exists.
28
IG2 power supply
Ignition switch: ON
System voltage
29
Illumination earth
Always
Continuity exists.
30
ILL power supply
Lighting switch: ON
System voltage
31
-
-
-
32
Input from the engine-A/T-ECU (A/C2)
When the A/C is under low load
System voltage
33
Input from the compressor relay
Compressor: ON
System voltage
34
Input from the engine-A/T-ECU (A/C1)
When the A/C is stopped
0 V
When the A/C is operating (When the compressor is operating)
System voltage
35
-
-
-
36
ACC power supply
Ignition switch: ACC
System voltage