Terminal No.
|
Check items
|
Check conditions
|
Normal conditions
|
1
|
Interior temperature sensor
|
Sensor temperature: 25°C (4kΩ)
|
2.1-
2.7V
|
2
|
Output to blower pulse controller
|
When the blower is operating.
|
0 -
2.5V (Effective alternating voltage)
|
3
|
Back-up power supply
|
Always
|
System voltage
|
4
|
Input from heater water temperature sensor
|
Sensor temperature: 25°C (4kΩ)
|
2.1 -
2.7V
|
5
|
Input from air mixing door control motor potentiometer
|
When the damper flaps is moving to the MAX HOT position.
|
4.1 -
4.6 V
|
6
|
Input from mode selection damper control motor potentiometer
|
When the damper is moved to the DEF position.
|
4.1 -
4.6 V
|
7
|
Input from the outside thermo sensor
|
Sensor temperature: 25°C (4kΩ)
|
2.1 -
2.7 V
|
8
|
Input from the air thermo sensor
|
Sensor temperature: 25°C (4kΩ)
|
2.1 -
2.7 V
|
9
|
Photo sensor (-)
|
Brightness is 0 lux
|
4.9 -
5.1 V
|
Brightness is 100000 lux or more
|
Approximately 0 V
|
10
|
Potentiometer power supply
|
Always
|
5 V
|
11
|
Input from the A/C pressure sensor
|
2.6 Mpa
|
3.9 V
|
12 -
15
|
-
|
-
|
-
|
16
|
Rear defogger
|
When the rear defogger is operating.
|
2.0 V or less
|
When the rear defogger is stopped
|
System voltage
|
17
|
Diagnosis set
|
Ignition switch: ON
|
A voltmeter needle fluctuates between 0 and 12 V.
|
18
|
Input from diagnosis
|
Ignition switch: ON
|
Approximately 5 V
|
19
|
Photo sensor (+)
|
Always
|
0 V
|
20
|
Sensors and potentiometers earth
|
Always
|
0 V
|
21
|
Air outlet changeover damper motor (FACE)
|
When the damper is moved to the FACE position.
|
10 V
|
When the damper is moved to the DEF position.
|
Faint voltage (0.5 V)
|
22
|
Air mix damper motor (MAX COOL)
|
When the damper flaps is moving to the MAX COOL position.
|
10 V
|
When the damper flaps is moving to the MAX HOT position.
|
Faint voltage (0.5 V)
|
23
|
outside/inside air selection damper control
motor (outside)
|
When the damper is moved to the inside air recirculation position
|
10 V (When the motor is stopped)
|
When the damper is moved to the outside air inside air intake position
|
2.0 or less
|
24
|
Mode selection damper control motor and potentiometer
(DEF)
|
When the damper is moved to the FACE position.
|
Faint voltage (0.5 V)
|
When the damper is moved to the DEF position.
|
10 V
|
25
|
Air mixing door control motor and potentiometer (MAX
HOT)
|
When the damper flaps is moving to the MAX COOL position.
|
Faint voltage (0.5 V)
|
When the damper flaps is moving to the MAX HOT position.
|
10 V
|
26
|
outside/inside air selection damper control
motor (inside)
|
When the damper is moved to the inside air recirculation position
|
2.0 V or less
|
When the damper is moved to the outside air inside air intake position
|
10 V (When the motor is stopped)
|
27
|
Earth
|
Always
|
Continuity exists.
|
28
|
IG2 power supply
|
Ignition switch: ON
|
System voltage
|
29
|
Illumination earth
|
Always
|
Continuity exists.
|
30
|
ILL power supply
|
Lighting switch: ON
|
System voltage
|
31
|
-
|
-
|
-
|
32
|
Input from the engine-A/T-ECU (A/C2)
|
When the A/C is under low load
|
System voltage
|
33
|
Input from the compressor relay
|
Compressor: ON
|
System voltage
|
34
|
Input from the engine-A/T-ECU (A/C1)
|
When the A/C is stopped
|
0 V
|
When the A/C is operating (When the compressor is operating)
|
System voltage
|
35
|
-
|
-
|
-
|
36
|
ACC power supply
|
Ignition switch: ACC
|
System voltage
|