<2000>
   
Terminal No.
Check items
Check conditions
Normal conditions
18
Output to fan controller
Air conditioner switch: OFF
4.9 - 5.1 V
Air conditioner switch: ON
0 V
21
Output to A/C compressor
A/C compressor relay: OFF
System voltage
A/C compressor relay: ON
0 V
46
A/C pressure sensor power supply
Always
4.9 - 5.1 V
57
A/C pressure sensor earth
Always
0 V
61
Input from A/C-ECU (A/C2)
When the A/C is under low load
System voltage
62
Input from A/C pressure sensor
2.6MPa
3.9 V
83
Input from A/C-ECU (A/C1)
When the A/C is in operation (When the air thermo sensor detects 3°C or more).
System voltage

<2400>
   
Terminal No.
Check items
Check conditions
Normal conditions
17
Output to fan controller
Air conditioner switch: OFF
4.9 - 5.1 V
Air conditioner switch: ON
0 V
16
Output to A/C compressor
A/C compressor relay: OFF
System voltage
A/C compressor relay: ON
0 V
97
A/C pressure sensor power supply
Always
4.9 - 5.1 V
96
A/C pressure sensor earth
Always
0 V
78
Input from A/C-ECU (A/C2)
When the A/C is under low load
System voltage
118
Input from A/C pressure sensor
2.6MPa
3.9 V
69
Input from A/C-ECU (A/C1)
When the A/C is in operation (When the air thermo sensor detects 3°C or more).
System voltage

©2004 Mitsubishi Motors Corporation