| CHECK THE AIR MIXING DOOR CONTROL MOTOR AND POTENTIOMETER
|
|
CHECK THE AIR MIXING DOOR CONTROL MOTOR
Battery connection (+) terminal
|
Battery connection (-) terminal
|
Lever operation
|
1
|
3
|
Rotate to the HOT position.
|
3
|
1
|
Rotate to the COOL position.
|
Potentiometer check
- When the resistances between terminals 2 and 5 as well as terminals 5 and 6 are measured at the air mixing door motor check, the resistance value should change gradually within the standard value.
Standard value: Approximately 0.65(MAX COOL) -
5.35(MAX HOT) kΩ
|
| MODE SELECTION DAMPER CONTROL MOTOR AND POTENTIOMETER CHECK
|
| |
MODE SELECTION DAMPER CONTROL MOTOR CHECK
Battery connection (+) terminal
|
Battery connection (-) terminal
|
Lever operation
|
1
|
3
|
Rotate to the DEF position.
|
3
|
1
|
Rotate to the FACE position.
|
|
|
Potentiometer check
- When the resistances between terminals 2 and 5 as well as terminals 5 and 6 are measured at the mode selection damper control motor check, the resistance value should change gradually within the standard value.
Standard value: Approximately 0.65(DEF position) -
5.35(FACE position) kΩ
|
| BLOWER MOTOR CHECK
Execute actuator test item No.01 to 04 by using MUT-II with the vehicle body, and check that the blower motor works normally (Refer to  ).
|